Tier: III | Services: Colocation, Disaster Recovery
This site is a Tier III datacentre offering a range of colocation, disaster recovery and connectivity services. We can offer 24x7x365 support from this site.
download specification datasheet
Docklands Resilience Resilience
Every rack benefits from A & B power feeds, supported by N+1 UPS and Generator infrastructure. In line with our passion for the environment, a highly efficient UPS plant has been selected to maximize efficiency of power delivery. Standby power is provided via diesel generators that are capable of providing 4 days of continuous power at full load capacity. This is further supplemented by fuel standby contracts to ensure continuity of supply and a rigorous service and maintenance programme. The operating environment is maintained at optimum temperature and humidity by the chilled water cooling infrastructure, delivered via a dual fed highly resilient ring circuit. The Coreix power and cooling infrastructure is designed to be concurrently maintainable as per Tier III standards. All chillers and CRAC units are built on an N+1 configuration.
Docklands Security Security
Coreix is a firm believer that good security is at the heart of any successful datacentre. Security begins at the front gate; the entire site being 'non-branded' and being monitored by IP CCTV by our on-site NSI Gold accredited 24x7x365 security personnel. All plant equipment is self contained within the building.

A 'layered' approach to access is in operation, with each individuals being restricted to those areas to which they require access. All visitors to site must be pre-booked and are subject to screening at the entry points. Once on-site all personnel are processed at our secure reception. In addition to visual identity checks and processes, access to the technical areas is further restricted by entry cards. Each Data Hall has unique access protocols to ensure only authorised personnel and visitors are granted access as required.

Detailed specifications include:

24/7/365 manned NOC and on-site security team | Manned vehicle entry gate to site | Internal and External IP CCTV coverage | Man Traps between common areas and data halls | Digital Security for data halls | Full authentication and access control policy

This 'multi-layered' approach to Security is designed to prevent unauthorized access by checking that all visitors to site have been authorized, and ensures that if any level is breached there is another check immediately.